electric fan in spider/Milano temp switch
Respected Digestables,
I finally put an electric fan in my spider this weekend, bought a wiring kit
with temp switch probe/switch included.
The switch is set for 185F so I mounted it about 2" from the bottom of the
upper tank on the radiator, directly under the outlet for the upper hose.
I'm sure glad I put an override switch in because the temp gauge went up to
212F and the fan never came on! It went down when I switched it on remotely.
I can only assume that the water temp in the radiator never got to 185F? I
shorted the wires at the switch and the fan worked,i.e. the wiring is OK.
It's been suggested that a Milano temp switch will fit nicely into one of
the recessed hex cap plugs in the head, is that any year Milano?
I can get a Beck Arnley switch at a local Napa for $11.95. Obviously I'd
rather not count on my memory to switch the fan on and off manually as
required. Any input is welcome!!!
Dave Partridge
76 Spider
"Free advice is worth what you make of it."
--